BoxedApp 提供了一個虛擬檔案系統和虛擬環境 。The virtual file system and the virtual registry are in the process memory. Each call to a file system (create file, open file and so on) and each call to registry are preprocessed by the BoxedApp's engine.
USB for Remote Desktop
當 USB 設備連接到本地工作站時,USB for Remote Desktop 可以讓您使用這些設備在終端伺服器運行操作,就如直接插在伺服器中使用一樣。 For Windows, Linux and Windows CE.
The program consists of Server and Workstation parts. The Workstation part is installed on the local computer or thin client where USB devices are physically plugged. The Server part is installed on the remote side you are connecting to via Microsoft RDP, Teradici PCoIP or Citrix ICA. The Server part makes redirected USB devices available for remotely logged users.
The program supports a wide range of USB hardware and does not require any special configuration.
特色
Supports Windows and Linux as a remote desktop in different configurations
USB for Remote Desktop supports Windows and Linux remote desktops. It does not matter what protocol is used for accessing the remote side — Microsoft RDP, Teradici PCoIP, Citrix ICA. It does not matter what environment is used — Microsoft Azure, Microsoft Terminal Services, Hyper-V, Citrix XenApp, Citrix XenDesktop, VMware View, Amazon Workspaces and others.
Any compatible Windows and Linux Client software can be used for accessing remote Windows and Linux side. And there is no need to change firewall settings.
Driver-free solution
USB for Remote Desktop does not require USB device drivers on the local machine or thin client. So, any new USB device can be redirected to the remote desktop session without installing USB device drivers.
Works with any USB devices
The program is not limited to some specific models of USB devices. It is compatible with any of them. So, it is really universal solution for USB device redirection. Even the most exotic USB devices can be redirected to your remote desktop environment.
Auto-redirecting of hot-plugged USB devices
Using the Administrative Utility, USB for Remote Desktop can be configured to redirect any newly plugged USB device immediately and automatically. You don't have even to divert your attention away from the working process. The program will redirect the USB devices automatically every time you plug them in.
USB port redirection
In some cases it is really convenient to use some dedicated USB port for redirection. In such case any USB device being plugged to that port will be redirected to remote side. All other devices will be for local use only.
Ready for Enterprise
For large installations, it’s possible to configure the program for local and domain users remotely. The configuration can be done via Active Directory allowing to pre-set needed settings or even disable USB redirection for specified users or just for specific types of USB devices.
Operating System Support
Windows
Windows 10
Windows 8 and 8.1
Windows 7
Windows Vista
Windows Server 2012 and 2012 R2
Windows Server 2008 and 2008 R2
Windows Server 2003
Linux
OS: Linux kernel 2.6.12 or greater, FreeRDP or C...
Primo Ramdisk 是 VSuite Ramdisk 的第二代產品。相比 VSuite Ramdisk,它實現了更多的功能,更好的性能,以及更友好的使用者介面。和 VSuite Ramdisk 同樣,Primo Ramdisk 提供了對傳統硬碟性能瓶頸問題的有效解決方案。它採用獨特的軟體演算法,高效率地將實體記憶體虛擬成物理硬碟,使得對硬碟檔的資料讀寫轉化為對記憶體的資料訪 問。由於實體記憶體的存取速度遠遠超過傳統硬碟,因此可以極大的提高資料讀寫速度,從而突破硬碟瓶頸,飛速提升電腦性能。
Primo Ramdisk 具有一系列強大的功能和選項以使性能最大化,並使軟體具有廣泛的應用性。Primo Ramdisk 可支援創建128個虛擬硬碟,每個虛擬硬碟可被 Windows 系統識別為真實物理硬碟或邏輯硬碟。虛擬硬碟可被格式成 Windows 支持的檔案系統,並允許使用者根據需要對檔案系統進行自訂設置。
由於記憶體具有斷電資料消失的特性,在某些應用環境中正好可以起到保護資料安全的作用,防止重要資料殘留在物理硬碟中。Primo Ramdisk 同時提供了強大的鏡像檔功能,支援關機時將虛擬硬碟的內容自動保存到鏡像檔以及開機時自動從鏡像檔載入內容到虛擬硬碟等功能,使記憶體虛擬硬碟的內容 在電腦開關機時仍可繼續存在。Primo Ramisk 支援諸多高級鏡像功能,如定時保存、 即時保存、快速保存以及延遲載入等,可以更好地滿足用戶多種需求。
此外,Primo Ramdisk 提供了獨特的記憶體管理特性,更有效地利用實體記憶體。它支援動態記憶體管理,可以根據需要動態地分配或釋放記憶體,從而更合理地使用實體記憶體,避免長期無意義地 佔用記憶體。Primo Ramdisk 同時實現了未識別記憶體管理介面 (UIMMI),可以使用未識別記憶體創建虛擬硬碟,從而間接地支援在32位元作業系統上使用超過4GB的實體記憶體,避免實體記憶體的浪費。
除了創建記憶體虛擬硬碟,Primo Ramdisk 甚至可以創建混合虛擬硬碟和檔虛擬硬碟,極大地擴展了軟體的功能和應用範圍。
更新介紹
Greatly improve the read/write speed of both SCSI and Direct-IO ramdisks.
Redesign the program GUI for better user experience.
Support mounting image files. [Except Standard Edition]
Support saving the disk content to the image file before the computer enters the sleep or hibernate state. [Except Standard Edition]
Merge Standard, Professional, Ultimate editions into one package. And the program automatically switch the edition based on the license type, so you don't need to install the program again when you upgrade the program to an advanced edition.
Fix bug: Possible conflicts with certain drivers, especially intel wireless drivers, causing these drivers not working or BSOD.
Fix bug: Possible hangs on accessing a file-disk or hybrid-disk in Windows 8/10.
Fix bug: The program GUI possibly freezes while saving the image file or running other time-consuming operations.
Fix bug: The modification time of an image file is not updated after the program saves the ramdisk content to the image file.
Fix bug: Ramdisks did not save their content to image files at computer shutdown when Windows Fast Startup is enabled.
Fix bug: Some disk contents might not been saved to the image file in time during timing save.
Allow to keep original copy when creating a junction point.
Reduce the real storage size of a flat image file.
Add a switch in the Option dialog to quic...
Proxmox Mail Gateway 是一套高效將垃圾郵件和病毒過濾的軟體
為了確保有效的電子郵件通信,Proxmox Mail Gateway是一套高效將垃圾郵件和病毒過濾的軟體。Proxmox的郵件網可幫助您保護您的企業免受所有的電子郵件威脅如垃圾郵件、病毒和木馬等等。靈活的架構結合了用戶名單,基於Web管理,使您可以輕鬆控制所有傳入和傳出的電子郵件。保持一個專業的電子郵件的工作流程,可以獲得較高的商業信譽和客戶滿意度。
系統需求
Recommended Hardware
(depending on your email traffic and settings)
Multicore CPU: 64bit (Intel EMT64 or AMD64), for use as virtual machine activate Intel VT/AMD-V CPU flag
4 GB RAM
Bootable CD-ROM-drive or USB boot support
Monitor with a resolution of 1024x768 for the installation
1 Gbps Ethernet network interface card
Storage: at least 8 GB free disk space, best setup with redundancy, use hardware RAID controller with battery backed write cache (“BBU”) or ZFS. ZFS is not compatible with a hardware RAID controller. For best performance use Enterprise class SSD with power loss protection.
Minimum Hardware
CPU: 64bit (Intel EMT64 or AMD64)
2 GB RAM
bootable CD-ROM-drive or USB boot support
Monitor with a resolution of 1024x768 for the installation
Hard disk with at least 8 GB of disk space
Ethernet network interface card
Install as virtual host
For using Proxmox Mail Gateway on a virtualization platform use the same resource settings as you would use on physical hardware. The following platforms are supported:
Proxmox VE
Vmware vSphere™
Hyper-V™
KVM
Virtual box™
Citrix XenServer™
LXC container
...and others supporting Debian Linux as guest OS
版本比較
Annual Subscriptions for Proxmox Mail Gateway
PREMIUM
STANDARD
BASIC
COMMUNITY
Complete feature-set
GNU AGPL, v3 license
Access to Enterprise repository
Support via Customer Portal
Unlimited support tickets
Response time: 2 hours*
within a business day
Remote support (via SSH & HTTPS)
Complete feature-set
GNU AGPL, v3 license
Access to Enterprise repository
Support via Customer Portal
15 support tickets/year
Response time: 4 hours*
within a business day
Remote support (via SSH & HTTPS)
Complete feature-set
GNU AGPL, v3 license
Access to Enterprise repository
Support via Customer Portal
5 support tickets/year
Response time: 1 business day
Complete feature-set
GNU AGPL, v3 license
Access to Enterprise repository
Community support
StarWind Virtual SAN
通過在管理程序服務器之間簡單地鏡像內部硬盤和閃存,從而消除了對物理共享存儲的任何需求。它通過利用相同工作負載的硬體資源來降低虛擬化開支(資本和運營)。憑藉獨特的StarWind開發的技術,StarWind VSAN 以簡約資源保持高性能和數據高可用性。StarWind Virtual SAN使用商用現成硬體提供了性能和可靠性,無需昂貴的專有組件。
StarWind Virtual SAN比其他軟體定義存儲平台簡單,價格低廉,性能更高,功能更多。StarWind VSAN只需兩個節點即可進行簡單的基本配置,無需投票或仲裁設施,操作非常簡單。它降低了需要較少硬體的成本:沒有交換機,沒有強制閃存,沒有10GbE和更少的服務器。StarWind VSAN只需要兩個許可節點即可根據需要處理多個節點的基礎架構。基本配置支持許多類似解決方案中不可用的功能,例如異步複製,線內和脫機重複數據刪除,日誌結構化,多層RAM和閃存緩存。
StarWind VSAN支持融合場景,也可以在現有虛擬機管理程序服務器之上進行超融合。它運行在便宜的商用現成硬體上,不會造成硬體鎖定。許可證是永久的,因此它們永遠不會過期並導致更新的額外費用。與單一用途的開放源代碼免費軟件不同,StarWind VSAN使用內部開發的代碼,在全球範圍內已得到充分驗證,並且是原生Windows應用程序,無需任何定制的Linux / FreeBSD分支。StarWind VSAN受StarWind支持,並且還可以使用Microsoft和VMware支持服務。StarWind Virtual SAN與競爭對手的完全區別可以在這裡找到。
優點
特別簡單
StarWind Virtual SAN作為本機虛擬機管理程序組件或虛擬機運行,並且不需要任何深層存儲和網絡管理或UNIX管理技能。在Hyper-V,VMware或Windows中經驗最少的典型系統管理員可以安裝,配置和維護VSAN操作。
成本效益
StarWind Virtual SAN將成本降低至少一半,這意味著運營和資本支出。它消除了實際的物理共享存儲,相應的基礎架構,相關的部署和維護活動。StarWind VSAN適用於商品硬體,因此不僅購買和維護的硬體更少,而且所需的硬體價格低廉。
性能和功能
性能不受簡約硬體足蹟的影響,降低了部署和管理成本。StarWind Virtual SAN帶來了服務器端閃存和內存緩存,日誌架構和絕對簡約的I / O路徑。由此產生的性能無論是典型的虛擬設備還是物理共享存儲都無法匹敵。
系統需求
CPU
CPU: Intel Xeon E5620 (or higher) or equivalent AMD OpteronWith 75% of server workloads being virtualized, virtualization is just getting started. VDI and SMB clouds have just started to emerge and will grow rapidly in the next few years. As IT is moving forward at an ever-increasing pace, datacenters are becoming hyperconverged. The minimum recommended CPU is Intel Xeon E5620 or equivalent. Intel Xeon X5660 or equivalent can be used in order to maximize the performance.
RAM
RAM: 4GB is the minimum.
RAM amount that should be installed on a server that is running StarWind Virtual SAN. In case of implementing StarWind High Speed caching, an appropriate RAM amount should be installed additionally. The cache-dedicated RAM amount should be equal or higher than the one reserved for iSCSI targets caching.
In-line deduplication with LSFS requires 7.6 GB of RAM per 1 TB of deduplicated storage.
IMPORTANT NOTICE: Always reserve at least 4 GB RAM for Windows internal processes and the StarWind Virtual SAN engine.
Storage
• Har...